Attributes of Auxiliary Function to be assigned to an input control.
Bits 0―4 Auxiliary function type
See Table J.5 — Auxiliary Function Type 2 types
Bit 5 Critical Control
0 = This function can be controlled by any compatible Auxiliary Input.
1 = This function can only be controlled by a critical Auxiliary Input (see ISO 15077)
Bit 6 Assignment Restriction
0 = Unrestricted. The operator or a Preferred Assignment command can assign this function. Operator assignments take precedence
1 = Restricted. This function, if assigned, can only be assigned as specified in the Preferred Assignment command. Even with this restriction, it can be unassigned.
Bit 7 Single-assignment
0 = Function can be assigned with other Auxiliary Functions to same input
1 = Function shall not be assigned with other Auxiliary Functions to same input